Horizontal HCS (Category M) - Filter Water Separators

Models HCS (End Opening)

Horizontal Coalescer Separators for Fixed Installation

6th Edition EI 1581, Category M, Type S Qualified

Category M Coalescer Separator housings are for Military F24, JP-8 or JP-5 fuel. Type S qualifications can be used at all filtration points in an aviation fueling system. Type S is meant to be used at filtration points where significant levels of water and dirt in the product can be expected. Facet HCS Series Horizontal Coalescer Separator housings fully comply with EI 1581, Category M, Type S requirements.

Reliable Performance

Facet coalescer separators are a result of over 75 years of continuous research and development to meet the ever demanding performance requirements in the aviation fuel handling industry. This, along with proven field performance, demonstrates Facet’s ability to provide quality products that meet current specifications as well as specific customer requirements for installations in refineries, bulk storage, terminals, heliports, airports, etc.

Models HCS (End Opening)

Horizontal Coalescer Separators for Mobile Equipment

6th Edition EI 1581, Category M, Type S Qualified

Category M Coalescer Separator housings are for Military F24, JP-8 or JP-5 fuel. Type S qualification can be used for mobile applications where minimum amounts of water and dirt in the product are expected. Facet HCS Series Horizontal Coalescer Separator housings fully comply with EI 1581, Category M, Type S requirements.

Reliable Performance

Facet coalescer separators are a result of over 75 years of continuous research and development to meet the ever demanding performance requirements in the aviation fuel handling industry. This, along with proven field performance, demonstrates Facet’s ability to provide quality products that meet current specifications as well as specific customer requirements for installations in refineries, bulk storage, terminals, heliports, airports, etc.

  • Designed to be used in:
    • Type S filtration points i.e. where significant levels of water and dirt in the product can be expected.
    • Type S-LW mobile applications i.e. where minimum amounts of water and dirt in the products are expected.
  • Can be supplied in horizontal configurations.
  • Can be supplied for different categories e.g. C or M.
  • EI 1596 Design & Construction
  • Welded carbon steel construction—other materials available on request • ASME Code, Section VIII construction, stamped and certified.

HCS Series (End Opening) Category M (Military) Type S

  • EI 1596 Design & Construction
  • Welded carbon steel construction—other materials available on request
  • ASME Code, Section VIII construction, stamped and certified
  • Design pressure: 150 psi @ 250 ˚F (10.3 bar @ 121 ºC) — other design pressures available on request • Inlet, outlet and drain connections permanently marked
  • Interior: Epoxy coated (EI 1541)
  • Exterior: Prime coated
  • Swing bolt head closures
  • Hinged end opening cover
  • Flanged inlet and outlet connections
  • Buna-N o-ring closure seal
  • Choice of rod or screw base coalescer cartridge mounting styles
  • 4” inlet/outlet cleanout/inspection connections (when permitted by design)
  • Knife edge cartridge mounting seals
  • Spider plate attached to vessel wall
    Options
  • Automatic air eliminator* with check valve
  • Pressure relief valve*
  • Differential pressure gauge*
  • Pilot control valve
  • Pilot tester
  • Water slug control valve
  • Electrical water-level alarm
  • Water drain valves
  • Liquid level gauge
  • Blind cover for pilot control mounting flange
  • Immersion heaters
  • Sampling probes*
    (* Mandatory for EI 1596 2nd Edition)

HCS Series (End Opening) Category M (Military) Type S

  • EI 1596 Design & Construction
  • Welded carbon steel construction—other materials available on request
  • ASME Code, Section VIII construction, stamped and certified
  • Design pressure: 150 psi @ 250 ˚F (10.3 bar @ 121 ºC) — other design pressures available on request
  • Inlet, outlet and drain connections permanently marked
  • Interior: Epoxy coated (EI 1541)
  • Exterior: Prime coated
  • Swing bolt head closures
  • Hinged end opening cover
  • Victaulic inlet and outlet connections
  • Buna-N o-ring closure seal
  • Choice of rod or screw base coalescer cartridge mounting styles
  • Knife edge cartridge mounting seals
  • 4" inlet/outlet cleanout/inspection connections (when permitted by design)
  • Spider plate attached to vessel wall
    Options
  • Water defense system*
  • Automatic air eliminator* with check valve
  • Pressure relief valve*
  • Differential pressure gauge*
  • Pilot control valve
  • Blind cover for pilot control mounting flange
  • Sampling probes*
    (* Mandatory for EI 1596 2nd Edition)

Contact Liquip for parts suitability and ordering. 

 